KOOLTHERM K17 PDF

The wall dry–lining insulation shall be Kingspan Kooltherm® K Insulated Dry– lining Board comprising a mm plasterboard facing bonded to ____mm. Kingspan Kooltherm K Super high performance rigid thermoset phenolic insulation; Fibre-free, closed cell insulation core; 3-in-1 insulation, dry-lining and . Kooltherm K17 Insulated Dry-lining Board is an insulated plasterboard for traditional dot and daube plaster adhesive fixing. The tapered edge board enables flat.

Author: Tesida Mazukasa
Country: Sri Lanka
Language: English (Spanish)
Genre: Sex
Published (Last): 25 October 2007
Pages: 175
PDF File Size: 14.64 Mb
ePub File Size: 6.14 Mb
ISBN: 676-8-86014-776-4
Downloads: 43827
Price: Free* [*Free Regsitration Required]
Uploader: Zulabar

The contribution of the product Total R-values depends on installation and environmental conditions. System R-values Click on the specific application types below to view their System R-values. K17 Insulated Dry—lining Board has a gypsum plasterboard face. The particular system employed will depend on the construction or design of the wall to which Kingspan Kooltherm K17 Insulated Plasterboard is to be fixed.

Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. For any enquiries, call 1 23 23 1 or send an email to info kingspaninsulation. Test – BS —7: Gun apply a continuous blob of construction adhesive around perimeter wall and ceiling junctions, and around any openings, such as windows and doors, in order to provide a seal.

Mechanical Fixing Directly to Masonry Substrates This method is for application to fair finished brick, block and concrete cavity walls where K17 is to be finished with gypsum plaster.

The Reverse Face The reverse facing of K17 Insulated Plasterboard is a tissue based facing autohesively bonded to the insulation core during manufacture. We use cookies on our website www. Construction Adhesive Bonding View Instructions. Nailable plugs are recommended to complement the plaster dab bond. Kingspan Kooltherm K17 should be screw fixed to each metal framing section with self drilling and tapping, countersunk, surface coated to avoid corrosionscrews placed at mm centres.

  CERITA LAILA MAJNUN PDF

Timbers must offer a minimum 20 mm support to all four edges of the board. K17 Insulated Plasterboard can be fixed by the use of proprietary metal framing systems to brick, block or concrete walls.

Kooltherm K17 | Forman Building Systems

Drywall screws or, alternatively, galvanised clout koltherm, long enough to allow a minimum 25 mm penetration of the timber, should be placed at mm centres and not less than 10 mm from the edges of the board.

Please note that the reflective surfaces on this product are designed to enhance their thermal performance. Refer to fixing manufacturer instructions for more information. Cutting Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

Boards that iooltherm been allowed to get wet should not be used. The method kootlherm involves setting out a continuous fillet of gypsum adhesive around perimeter wall and ceiling junctions, and around any openings in order to provide a seal. Test – BS —6: Please contact us for more information.

Mechanical Fixing to Metal Furring Systems K17 Insulated Plasterboard can be fixed by the use of proprietary metal framing systems to brick, block or concrete walls.

The reverse facing of K17 Insulated Plasterboard is a tissue based facing autohesively bonded to the insulation core during manufacture. Click on the specific application types below to view their System R-values. The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils.

Care should be taken not to overdrive screws. Kooltherm K17 Insulated Plasterboard. Send Us An Enquiry. Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs. Short lengths of metal framing should be fixed horizontally between the vertical pieces at skirting level, at the midpoint of the board and just below the ceiling or soffit level.

  BOURDIEU FOR BEGYNDERE PDF

Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Bostik adhesive is applied to the wall surface in strips to a predetermined pattern that coincides with the edges of the koolhherm, and then a further strip is applied horizontally at the midpoint koiltherm the board.

Ensure that the blobs adjacent to a board joint are approximately 25 mm in from the edge to avoid bridging the joint.

Wall mounted fittings such as electrical sockets should be fitted so as to take into account the additional wall thickness. The wall should be sound, dry and level as surface irregularities may impede fixing of the board.

52.5mm Kooltherm K17 – Kingspan – Phenolic Insulation with Plasterboard – pack of 15

Heavy surface mounted fittings will require provision for the fixing load to be applied direct to the supporting wall and not to the K17 in isolation. Product Description The Front Facings The front facing k71 K17 Insulated Plasterboard is a tapered edge gypsum based plasterboard which readily accepts dry—jointing materials, plaster skim or direct decoration.

Fixing should employ the same method as is used for the plain wall areas. Adhesives containing such solvents should not be used in association with this product.